Division / Type | SVS-300 | SVS-500 | SVS-1000 | SVS-1500 | SVS-2000 | Proper Form of Evaporation | kg/h | 300 | 500 | 1,000 | 1,500 | 2,000 | Max. Working Pressure | kg/㎠ | 7 / 10 {0.7 / 1.0 MPa} | Efficiency | % | More than 88% ( More than 90% ) | Electric Transmission Area | ㎡ | 6.5 | 7.5 | 9.9 | 15.5 | 18 | 23 | Weight | Ton | 1.2 | 2.0 | 2.5 | 2.9 | 3.2 | 3.8 | Titration | ℓ | 375 | 451 | 602 | 920 | 1370 | 1700 | Fuel Consumption | Light Oil | kg/h | 20.7 | 34.5 | 69.1 | 103.6 | 138.2 | LNG | N㎥/h | 21.6 | 35.9 | 71.9 | 107.8 | 143.7 | LPG | N㎥/h | 9.5 | 15.9 | 31.8 | 47.7 | 63.6 | Heavy Oil | kg/h | 20.9 | 34.9 | 69.8 | 104.6 | 139.5 | Capacitance of Electric | kW | 1.37 | 2.05 | 3.7 | 5.5 | 6.7 | Joint Valve
| Main Steam Valve | A | 40 | 40 | 50 | 65 | 65 | Progression Valve | 20 | 20 | 25 | 25 | 25 | Drainage Valve | 40 | 40 | 40 | 40 | 40 | Safety Valve | 40 | 25 | 32 | 40 | 40 | Drain Oil Valve | 15 | 15 | 15 | 20 | 20 | Fuel Gas | 25 | 32 | 32 | 32 | 32 | Chimney | ømm | 250 | 250 | 300 | 300 | 350 | Minimum Dimension | Width | mm | 1,300 | 1,340 | 1,490 | 1,600 | 1,700 | 1,830 | Length | 1,600 | 1,650 | 2,100 | 2,270 | 2,420 | 2,660 | Height | 1,930 | 2,050 | 2,254 | 2,360 | 2,490 | 2,500 | | | mm | 1,700 | 1,740 | 1,800 | 1,980 | 2,080 | 2,230 | | 2,000 | 2,050 | 2,300 | 2,420 | 2,580 | 2,800 | | 2,250 | 2,370 | 2,550 | 2,730 | 2,850 | 2,950 |
※ Low calorific power of fuel ① LNG:41.45 MJ/N㎥{9,900kcal/N㎥}, ② LPG{Propane}:93.7 MJ/N㎥{22,380kcal/N㎥}, ③ Light Oil:43.12 MJ/kg{10,300kcal/kg}, ④ Heavy Oil:42.7 MJ/kg{10,200kcal/kg}
※ The specification list are subject to change without prior notice to improve the performance and technology development.
| |
|
|
|
|